Does a stovepipe need special clearance to combustibles.
Wood burning stove pipe clearance.
Clearance clearance select items sale sale select items compare castle pellet stoves serenity freestanding 1500 sq.
This beautiful 3 16 in.
Other combustibles other combustible materials such as firewood paper curtains and plastics should be kept at least 36 inches from the stove.
Posted on oct 18 2015 at 9 14 am.
Us stove 1 200 sq.
Double wall stove pipe on the other hand requires only 8 inches of clearance from the ceiling and 6 inches from a wall.
Clearances far stove and stovepipe from walls and floor.
Just because the stoves clearances can be reduced using a rear heat shield does not mean that the pipes clearances automatically fall into place.
Using a heat shield on a single wall stovepipe allows you to reduce the clearances from 18 to 6 to the wall and 9 to the ceiling.
Nfpa 211 standard for chimneys fireplaces vents and solid fuel burning appliances reader comment.
A 6 inch pipe would need a 42 inch diameter hole cut through a.
Steel stove is also one of the cleanest burning epa certified stoves on the market without catalyst.
Stovepipes like fireplaces wood burning stoves must be vented to the outside of the building.
The clearances are large because they apply to all shapes sizes and designs of stoves that have not been tested to determine the actual clearances.
Clearances indicated in table 1 below are the minimum clearances from wood burning stoves to unprotected combustible wall and ceiling surfaces.
Check the clearance chart.
Table 1 minimum clearances from wood burning stoves to.
Once these clearances are met you must convert your stove pipe to class a chimney pipe for proper venting of your stove.
Wood stove wall clearances primer.
Clearance should be three times the diameter of the pipe e g a 6 inch pipe needs 18 inches of clearance.
Use a thimble the clearance must be three times the pipe diameter.
Many think stovepipe can run from the wood stove right up through the ceiling and roof.
Defender wood burning stove with legs blower us1100e bl.
Details about pellet stove clearance distances and pellet stove chimney or vent termination clearance distances from various building features are now found.
At pellet stove manuals.
The clearance for an uncertified radiant stove is 1200 mm 48 in and for a stove with a sheet metal jacket or casing the clearance is 900 mm 36 in.
How to apply nfp 211 to wood stove fire clearances.
Product rating is 4.
4 1 41 was save.
Stove pipe don t forget to check the pipe clearances.
Any area within 36 inches of the wood stove should be covered as shown in figure 2.